Home

Albrecht AE5280 CB-Radio

Albrecht AE5280 CB-Radio

Albrecht AE5280 Block Diagram
Click on parts to view parts description
AE5280 PCB 2SC2078 2SC2314 TDA2003 BA403 Dual OP-AMP
CT1: IF Frequency 10.240MHz
CT2: Reference Frequency 4.5MHz
RV1: Squelch
RV2: S-Meter
RV3: Power-Meter
RV4: AM Modulation
RV5: FM Modulation

Conversion instructions AE 5280 channel extension (only admissible for export customers) the AE 5280 in German execution (80/12 channels) can be converted on some other standards:
Device open (with devices starting from summer 96 production date remove only lower cover with loudspeaker). Device in such a way put down that front plate of the viewer away-shows. On the front plate circuit board above the Squelchreglers 6 positions are CON 1 to detect (this are not soldered, with 40 FM CEPT everything soldered the solder joint programming fields for the microprocessor, with 80/12). Above the processor still some programming fields for AM-FM or CH 19 (1 bridge AF or CH 19) and the key for MEMORY channels or Channel 9 / BAND selection button (2 bridges for CH 9, 2 bridges for ME) are direct.
Pin 26 to 18Pin 25 to 18Pin 24 to 18Description
ConnectConnectConnect40 Channels (CEPT) - 26.965MHz to 27.405MHz
OpenOpenOpen80/12 Channels (Germany) - 26.565MHz to 27.405MHz
OpenConnectOpen40 Channels UK - 27.60125MHz to 27.99125MHz
ConnectOpenOpen120 Channels Polish - 26.510MHz to 27.850MHz
ConnectConnectOpen240 Channels Polish - 26.060MHz to 28.750MHz
OpenConnectConnect400 Channels - 25.165MHz to 29.655MHz
ConnectOpenConnect240 Channels - 26.065MHz to 28.755MHz
Consider please:
With 120 to 400 channel programming one still the MEMO switch on channel 9 key changes must, since only this key can be used as BAND selector switches. With devices starting from summer there are 96 in addition per 2 bridges ME and CH 9. The bridges with ME remove and with CH 9 solder. With devices, which do not have yet these programming bridges, one must remove the front screen and separate both (!) conductive strips from the note tracer to the processor and again attach the tracer with two thin wires in pin 18 and 5 of the CPU (feasible only if one is experienced in handling SMD and microelectronics). In principle all channels are adjustably, however with losses in the performance upward and down after the change, (the devices operate with full performance reliably only on the middle tapes, for which the devices were adjusted by the factory). It can also occur that the PLL system not everywhere einrastet.(Neuabgleich L 17 necessarily). Evtl. C 62 around 10-15 pF and C 66 around 22-33 pF (paralle connection).
Conversion instructions AE 5212 channel extension (only admissible for export customers) the AE 5212 in Spanish execution (40/40 channels), starting from seriennummer 9503..... can be changed over to 240 channel standard:
Current plugs pull (do not switch off alone been sufficient! Device open (remove only lower cover with loudspeaker). Device in such a way put down that front plate of the viewer away-shows. On the front plate circuit board above the Squelchreglers the Connector CON is 1 to detect (a two-pole connecting plug with a wire link, with some devices is there can this position be also soldered in as-delivered condition) plug to pull or solder joint remove.
If the device was beforehand at least some minutes switched off, it can be put again into operation. Otherwise the reservoir capacitor C 207 must be unloaded by short circuit (e.g. with screwdriver) still briefly.
After restarting the coming on 240 channels (international channel raster in tapes A, b, c, d, e and F of 26.065 MHz to 28,755 MHz) operates the standard tape is tape C, which considers display been made in the display, selection by the past channel 9-Taster possible (called with some devices already band tracers).
In principle all channels are adjustably, however with losses in the performance upward and down after the change, (the devices operate with full performance reliably only on the middle tapes, for which the devices were adjusted by the factory). It can also occur that the PLL system not everywhere einrastet.(Neuabgleich L 17 necessarily). Evtl. C 62 around 10-15 pF (parallel-solder) increase.