Power Supply: 13,2 V | DC Current Meter | Oscilloscope | RF Power meter |
RF VTVM | AF Oscillator | FM Linear Detector | Dummy Load (50 ohm) |
AF VTVM |
Mic gain | Clockwise | ||
Meter SW | RF | ||
SWR/CAL Volume | Middle position | ||
RF Power | Clockwise | ||
Test frequency | 27.185 MHz |
Step | Condition | Adjustment | Procedure |
---|---|---|---|
1 | AM 27.185 MHz No Mod. CEPT Mode | VR406 | Adjust for 3.9 Watt on the WattMeter |
2 | AM 27.185 MHz No Mod. Internationel Mode | VR401 | Adjust for 15 Watt on the WattMeter |
3 | AM 27.185 MHz No Mod. | VR201 | Adjust for RF Meter at "9" just light on |
4 | AM 27.185 MHz 1 kHz 30 mV Mod. | VR405 | Adjust 90% negative modulation |
5 | FM 27.185 MHz No Mod. | VR400 | Adjust for +/- 1.9 kHz Deviation |