Power Supply: 13,2 V | DC Volt Meter | Oscilloscope | Frequency Counter |
RF Power | Clockwise |
Step | Condition | Adjustment | Procedure |
---|---|---|---|
1 | RX AM Channel 20 Band C | L404 | Connect Frequency Counter to IC401 Pin 1 Adjust for 10.240MHz +/- 20Hz |
2 | RX AM Channel 20 Band C | L402 | Connect Voltmeter to TP1 Adjust for 2,8Volt +/- 0,1Volt |
3 | RX AM Channel 1 Band A Channel 40 Band F | Check | Connect Voltmeter to TP1 1,8 Volt +/- 0,1 Volt @ Band A and 4,3 Volt +/- 0,1 Volt @ Band F |
4 | TX AM Channel 20 Band C | L403 | Connect Voltmeter to TP1 Adjust for 2,7 Volt +/- 0,1 Volt |
5 | TX AM Channel 1 Band A Channel 40 Band F | Check | Connect Voltmeter to TP1 1,5 Volt +/- 0,1 Volt @ Band A and 4,8 Volt +/- 0,1 Volt @ Band F |
6 | RX AM Channel 20 Band C | L401 | Connect Frequency Counter to IC401 Pin 8 Adjust for 37.900MHz +/- 20Hz |