Power Supply: 13,8 V | Frequency Counter | DC Voltmeter | Oscilloscope |
Step | Condition | Adjustment | Procedure |
---|---|---|---|
1 | CH: 40 Band: E Mode: RX AM Clarifier: Center | L12 | Connect DC Voltmeter to TP2 ( R122). Adjust L12 for 6 V +/- 0.1 V on DC Voltmeter. Confirm 2 V on CH 1 Band A. |
2 | CH: 19 Band: C Mode: RX AM/FM Clarifier: Center | L13 | Connect Oscilloscope to TP3. Adjust L13 for maximum reading on Oscilloscope. |
3 | CH: 19 Band: C Mode: RX AM/FM Clarifier: Center | L14 | Connect Frequency Counter to TP3 (R73). Adjust for 16.490MHz +/- 20Hz on Frequency Counter. |
4 | CH: 19 Band: C Mode: RX USB Clarifier: Center | L15 | Connect Frequency Counter to TP3 (R73). Adjust for 16.4925MHz +/- 20Hz on Frequency Counter. |
5 | CH: 19 Band: C Mode: RX LSB Clarifier: Center | L16 | Connect Frequency Counter to TP3 (R73). Adjust for 16.4875MHz +/- 20Hz on Frequency Counter. |
6 | CH: 19 Band: C Mode: RX USB Clarifier: Center | L24 | Connect Frequency Counter to TP4 (R104). Adjust for 10.6975MHz +/- 20Hz on Frequency Counter. |
7 | CH: 19 Band: C Mode: RX LSB Clarifier: Center | L23 | Connect Frequency Counter to TP4 (R104). Adjust for 10.6925MHz +/- 20Hz on Frequency Counter. |
8 | CH: 19 Band: C Mode: TX AM Clarifier: Center | L15 | Connect Frequency Counter to TP5 (R82). Adjust for 10.695MHz +/- 20Hz on Frequency Counter. |