President Herbert CB-Radio


ALIGNMENT PROCEDURE


CARRIER OSCILLATOR PORTION


Test equipment required:
Power Supply: 13,8 VOscilloscopeDummy Load 50 ohmFrequency Counter

Preparation alignment:
Channel:40
StepConditionAdjustmentProcedure
1RX Band C
Channel 20
L701Connect DC-Voltmeter to TP1. Adjust for 2,4Volt +/-0,1Volt
2TX Band C
Channel 20
L702Connect DC-Voltmeter to TP1. Adjust for 2,4Volt +/-0,1Volt
3RX Band C
Channel 20
CT701Connect Frequency Counter to TP 3. Adjust for 37.900MHz