Power Supply: 13,8 V | Oscilloscope | Dummy Load 50 ohm | Frequency Counter |
Channel: | 40 |
Step | Condition | Adjustment | Procedure |
---|---|---|---|
1 | RX Band C Channel 20 | L701 | Connect DC-Voltmeter to TP1. Adjust for 2,4Volt +/-0,1Volt |
2 | TX Band C Channel 20 | L702 | Connect DC-Voltmeter to TP1. Adjust for 2,4Volt +/-0,1Volt |
3 | RX Band C Channel 20 | CT701 | Connect Frequency Counter to TP 3. Adjust for 37.900MHz |