President Harry CB-Radio


ALIGNMENT PROCEDURE


CARRIER OSCILLATOR PORTION


Test equipment required:
Power Supply: 13,8 VOscilloscopeDummy Load 50 ohmFrequency Counter

Preparation alignment:
Channel:40
StepConditionAdjustmentProcedure
1MODE: TX FML702Connect Oscilloscope to TP1 and adjust for 4,5V +/- 0.1V
2MODE: RX FML701Connect Oscilloscope to TP1 and adjust for 4,5V +/- 0.1V
3MODE: RX FMCHECKConnect the Frequency Counter to Ant. jack an scheck frequency for 27.405 MHz /- 20 Hz